R22 pressures

Table 1 (continued) DuPont™ Freon®22 Saturation Properties — Temperature Table. 7. Table 2 DuPont™ Freon®22 Superheated Vapor — Constant Pressure Tables. V = Volume in m3/kg H = Enthalpy in kJ/kg S = Entropy in kJ/kg•K Saturation Properties in ( ) 8. Table 2 (continued) DuPont™ Freon®22 Superheated Vapor — Constant Pressure Tables.

R22 pressures. Whether you have an established pressure washing business or you're just getting started, our pressure washing equipment list will help ensure you have everything you need. If you ...

mitsubishi mr slim R22 proper pressures @94 degrees. I have worked a Mitsubishi Mr slim with freon R22 and was wondering why the liquid line is cool and sweating back to condensing unit.What is the proper liquid and suction line pressures for this system on a 92 degree day. Mini's, while technically a split system, are configured differently ...

R-22 Refrigerant Fact & Information Sheet. R-22 refrigerant, or Freon, was and still is one of the most popular refrigerants used in the world. R-22 is an HCFC refrigerant and can harm the Ozone layer. It was originally invented by a partnership with General Motors and the DuPont company all the way back in the 1930’s.R22 changes from a liquid to a gas in the evaporator coils of the air handler. Normal temperatures: With compressor running and as reference, on a 90 degree F. day: - …R22 system, 3 ton condenser, high side pressure is415/156, r22 system, 3 ton condenser, high side pressure is415/156, low side is 85/50, the air temp is 98,wet bulb is 71, vapor line temp. is 72. the subcooling is correct. but temps and pressure are to high.Aug 21, 2018 · August 21, 2018. R-22 was the most popular refrigerant used in commercial and residential air conditioning units for many years because it was considered a safe and cost-efficient refrigerant choice by the HVACR industry. But as anyone in the industry knows, R-22 was phased out in the U.S. beginning in 2010 because it is ozone depleting. R-22 Low-Side Turn-On Pressure = 50 psig (R22 at 30 deg F) is a typical pressure at which the HVACR compressor/condenser will turn-on 100 psig (R 22 at 85 deg F) is a typical pressure at which the HVACR compressor will turn off [Questionable, further research in process - Ed.]R134a has a lower thermal conductivity than R22, so an R134a system needs a larger heat exchanger. A system circulating R134a needs a dryer, because of the propensity of the refrigerant to absorb water. R134a swells the rubber components in the refrigeration system and causes leaks. R134a corrodes copper, so the system must …Refrigerant Pressure-Temperature Home Back. Choose Refrigerant: R-410A R-22 °C °F: Psig-40-39-38-37 ...

Make your job easier with our handy refrigerant pressure temperature HVAC app with R-22 included.In this video, I show how a Liquid Line Restriction Affects The Liquid Pressure and Subcooling. I go over the indicators of a Restriction such as vapor satur...Pressure- Temp Chart Physical Properties of Refrigerants R22 Environmental Classification Molecular Weight Boiling Point (1atm,°F) Critical Pressure (psia) Critical Temperature (°F) Critical Density(lb./ft^ 3) Liquid Density (20 °F,lb./ft^3) Vapor Density (bp,lb./ft^ 3) Heat of Vaporization(bp,BTU/lb.) Specific Head Liquid( 20 °F, BTU/lb. °F)R22 has a very similar boiling point to R290 (-41.4°F to 44°F; that’s only a 2.6°F difference). At 100°F, however, the pressure of R22 is 195.9 psig and the pressure of R290 has a pressure of 174.3 psig (check the R290 PT chart below). This is a 20+ psig difference and you will easily tell if you have an R290 or R22 freon.The high side guage was connected to the liquid line. Static, both guages are 160 psig. When the unit ran, BOTH guages dropped to about 130. The high side was perhaps 2-5 higher. The amp draw at the compressor was 8.6 RLA out of a 22.1 suggest maximum on the equipment sticker.

Actual Line Temp – Sat Temp = Total Superheat. 55°F - 37°F = 18°F. 18°F of Total Superheat > 9°F Target Superheat = Undercharged. Since the actual total superheat measured is higher than the target superheat, we would need to add refrigerant a little at a time until the superheat is the same as the target superheat.mitsubishi mr slim R22 proper pressures @94 degrees. I have worked a Mitsubishi Mr slim with freon R22 and was wondering why the liquid line is cool and sweating back to condensing unit.What is the proper liquid and suction line pressures for this system on a 92 degree day. Mini's, while technically a split system, are configured differently ... Condensing Unit. 1-1⁄2 HP R-22 condensing unit / evaporator assembly. Horizontal line-set sloped down from evaporator compressor. Optimized refrigerant charge / adjusted TXV superheat setting. Ran R-422D, R-427A, and R-438A with MO & POE (camera) 100°F Ambient / 0, 25, & 50°F Box Temps – “Dry Coil” tests. A pressure mark is a sign of physical damage to the inside of an LCD screen. It is related to, but not always synonymous with, the problem of dead or stuck pixels. Usually it is no...R22 Pressure Temperature Chart Printable PDF Temp er atu r e (° F ): Temp er atu r e (° C): R22 P r essu r e (p si g ):-60° F -51. 1° C -11. 9 psi g-55° F -48. 3° C -9. 2 psi g-50° F …

Places to eat in scottsboro alabama.

Refrigerant Pressure-Temperature Home Back. Choose Refrigerant: R-410A R-22 °C °F: Psig-40-39-38-37 ...R-134a TEMPERATURE PRESSURE CHART (Tabla de Temperaturas y Lecturas) Ambient Temperature °F / °C (Temperatura Ambiental) Low-Pressure Gauge (Puerto de Servicio del Lado de Baja Presion) High-Pressure Gauge (Puerto de Servicio del Lado de Lado de Alta Presion) 65°F (18°C) 25-35 psi / 172-241 kPa: 135-155 psi / 931-1069 kPa: 70°F (21°C) …R407c is an HFC refrigerant that will replace the R22 refrigerant, as per Montreal Protocol. It is a mixture of R32 (23%), R125 (25%), and R134a (52%) that has a boiling point of -46.84°F. The same as R22, due to useful pressure-temperature properties, R407c is used in air conditioning systems, cars, and refrigeration units. Below, you will ...Table 2 (continued) Freon™ 22 Superheated Vapor — Constant Pressure Tables V = Volume in m3/kg H = Enthalpy in kJ/kg S = Entropy in kJ/kg·K Saturation Properties in ( ) Freon™ 22 Refrigerant 18. Freon™ Refrigerant For more information on Freon™ refrigerants, visit freon.com ...The perfect refrigerant reading depends on several factors, like atmospheric pressure and temperature. I like to see an average range of 58-85 PSI on the low side and 120-300 PSI on the high side. These indicate that the unit is running okay and should be cooling properly. TL;DR: R22 is almost phased out and even banned.mitsubishi mr slim R22 proper pressures @94 degrees. I have worked a Mitsubishi Mr slim with freon R22 and was wondering why the liquid line is cool and sweating back to condensing unit.What is the proper liquid and suction line pressures for this system on a 92 degree day. Mini's, while technically a split system, are configured differently ...

R22, also known as HCFC-22, is a colorless gaseous hydrochlorofluorocarbon refrigerant commonly used in HVAC systems for residential air conditioning and refrigeration. Introduced in the 1970s, R22 became widely used as a refrigerant due to its stability, safety, and energy efficiency properties. However, R22’s chlorine content also makes it ... on R22.. i generally use a pressure reading of 150 PSI when the unit is not running on an average 75-80 degree day.. thats on both liquid and suction lines.. for the most part R22 runs pressures of 75-85 PSI suction and 210-225 liquid when the unit is running with proper charge on an average 80 degree day..R407c is an HFC refrigerant that will replace the R22 refrigerant, as per Montreal Protocol. It is a mixture of R32 (23%), R125 (25%), and R134a (52%) that has a boiling point of -46.84°F. The same as R22, due to useful pressure-temperature properties, R407c is used in air conditioning systems, cars, and refrigeration units. Below, you will ...R-22 Refrigerant Pressure-Temperature Chart Author: iGas cited at InspectApedia.com Subject: R22 Refrigerant pressure chart Keywords: R-22, R22, refrigerant,gas,pressure,temperature Created Date: 12/31/2018 2:21:34 PMThermodynamic properties of R22, like vapor volume, enthalpy and entropy at pressures from <i>30 to 260 psia</i>.For supercritical ethanol, the frictional pressure drop variation with the heat flux is insignificant, while the local heat transfer coefficient increases as the enthalpy increases. Ethanol gives better flow and heat transfer performance than R22 at supercritical pressures from 7.3 MPa to 10 MPa for heat fluxes of 1.1 × 10 5 –1.8 × 10 6 W m ...407C Pressures vs R22: An In-Depth Analysis. The pressure at which 407C and R22 work is one of the primary differences. R22 has a higher pressure than 407C, which indicates it takes more energy to compress and circulate. This can result in increased operational costs, and in certain cases, a shorter equipment lifespan.If the gauge above were connected to an R410a system, we would see the pressure is about 134 PSIG, which points at about 46°F on the R410a (pink) temperature scale printed on the face. If it were R22, the green scale would show us 75°F for the very same pressure. Superheat and subcoolingIn this HVAC Refrigerant Charging Video I go over what it means to have low R22 Freon or Low R410A Suction Vapor Pressure along with a Low Superheat. I expla...Existing units using R-22 can continue to be serviced with R-22. There is no EPA requirement to change or convert R-22 units for use with the new non-zone-depleting …R22 changes from a liquid to a gas in the evaporator coils of the air handler. Normal temperatures: With compressor running and as reference, on a 90 degree F. day: - …

The COP of R290 is 18.4% higher than R22, 24.8% than R407C and 14% than R410A for 1 TR system whereas; it is 7.9% larger than R22, 15.7% than R407C and 12.95% than R410A for 2 TR systems. The COP for R290 is the maximum among all the four refrigerants tested due to its best thermo physical properties. Because of lower …

Temperature and pressure chart for refrigerants R22, R410A, R12, R134A, R401A, R409A, R502, R404A, R507A, R408A and R402A. Search Search is the most efficient way to navigate the Engineering ToolBox. Temperature and pressure chart for refrigerants R22, R410A, R12, R134A, R401A, R409A, R502, R404A, R507A, R408A and R402A. Engineering ToolBox - Resources, Tools and Basic Information for Engineering and Design of Technical Applications!HVAC App to Calculate Superheat. Our Pressure Temperature Chart for the selected refrigerant is available for quick access; just use the button labeled (P/T). Use the refrigerant drop down for access to over 100 refrigerants. Plus and minus buttons add and subtract values in intervals of 1 to their related input fields.Table 2 (continued) Freon™ 22 Superheated Vapor — Constant Pressure Tables V = Volume in m3/kg H = Enthalpy in kJ/kg S = Entropy in kJ/kg·K Saturation Properties in ( ) Freon™ 22 Refrigerant 18. Freon™ Refrigerant For more information on Freon™ refrigerants, visit freon.com ...High oil pressure occurs when an unusually high amount of pressure is required to circulate oil through the engine of a car. Most cars have oil pressure gauges that show how much p...Temperature and pressure chart for refrigerants R22, R410A, R12, R134A, R401A, R409A, R502, R404A, R507A, R408A and R402A. Engineering ToolBox - Resources, Tools and Basic Information for Engineering and Design of Technical Applications!R22 Pressure Temperature Chart Printable PDF Temp er atu r e (° F ): Temp er atu r e (° C): R22 P r essu r e (p si g ):-60° F -51. 1° C -11. 9 psi g-55° F -48. 3° C -9. 2 psi g-50° F -45. 6° C -6. 1 psi g-49° F -45. 0° C -5. 4 psi g-48° F -44. 4° C -4. 8 psi g-47° F -43. 9° C -4. 1 psi g-46° F -43. 3° C -3. 4 psi gLearn how to calculate the high-side and low-side compressor pressure of an R22 refrigerant air conditioning system using the service manual and the …A pressure mark is a sign of physical damage to the inside of an LCD screen. It is related to, but not always synonymous with, the problem of dead or stuck pixels. Usually it is no...

Bifold closet door rough opening.

Hai di lao los angeles.

Maintaining an R410A system is more difficult than a R22 system. It is more complex and its composition with differing pressure triggers more maintenance concerns. 6. Safety. Well, generally R410A is safer than R22, given that it doesn’t destroy the ozone layer.R-410A systems operate at higher pressures than standard R-22 systems. Do not use R-22 service equipment or components on R-410A equipment. Ensure service equipment is rated for R-410A.! WARNING Refrigeration systems contain refrigerant under pressure. Extreme caution should be observed when handling refrigerants. Wear safety glasses …TEMPERATURE - PRESSURE CHART FOR R-22, R-410A, R-407C, R-134A & R-404A REFRIGERANTS FYI #289 9/17/2009. updated 10/10/2012. Data points are reproduced based on available information. Advantage assumes no responsibility or liabililty for data errors. ADVANTAGE Engineering, Inc. 525 East Stop 18 Road Greenwood, IN 46142 317-887-0729 fax: 317-881 ...145 °F. 571.7 psig. 150 °F. 607.6 psig. 155 °F. 645.2 psig. You can see that this R410A pressure chart includes high and low side pressures at temperatures ranging from -60 °F to 155 °F. Higher temperature equates to higher pressure. Here are 4 examples of how you can use this chart:The R-410A has about 40 percent less heat-carrying capacity than the R-22. This causes the reduction of the replacement between the two different compressors. If an R-22 compressor has R-410A refrigerant put into the system, the motors will overload and burn out. The overloading can also cause the motor to start tripping the breaker, shutting ...pressure replacement for R-22 in positive displacement, direct expansion (DX) air conditioners and heat pumps. This refrigerant is also suitable for use in many medium-temperature refrigeration systems that formerly used R-22. Freon™ 407C is the registered trademark for a blend of HFC-32/HFC-125/HFC-134a with a correspondingHVAC App to Calculate Superheat. Our Pressure Temperature Chart for the selected refrigerant is available for quick access; just use the button labeled (P/T). Use the refrigerant drop down for access to over 100 refrigerants. Plus and minus buttons add and subtract values in intervals of 1 to their related input fields.Compressor suction and discharge pressures for R448A relative to R22 are given below. It may be necessary to reset the pressure cutouts to compensate for the different pressures of the replacement refrigerant. This procedure should be done carefully to avoid exceeding the recommended operating limits of the compressor and other system components. ….

Thermodynamic properties of R22, like vapor volume, enthalpy and entropy at pressures from <i>30 to 260 psia</i>.Although the market prices change constantly, you can expect to pay $4-$6 dollars per pound for R410A. R22 can cost up to $35 per pound, though about $20 per pound, as this shot shows. Note the number of pounds and the cost. 5lbs of R22 is $169 or about $34 per pound. 10lbs of R22 is $219, or almost $22 per pound.Pirelli P Zero Tire Pressure Chart. Select Pirelli P Zero tire size to locate its greatest tire load limit at its predetermined tire inflation. Tire load limit and tire inflation settings may differ based on tire load range or ply rating. Check Pirelli P Zero tire sidewall for more information. Remember that psi esteem imprinted on the tire ... Refrigerant R22 - Thermodynamic Properties Thermodynamic properties of R22, like vapor volume, enthalpy and entropy at pressures from 30 to 260 psia. Refrigerants Commonly used refrigerants - the methane series, ethane series, propane series, cyclic organic compounds, zeotropic blends, azeotropic blends and organic compounds. Normal operating pressures for R22 are between 260 psig (at 120°F) and 76 psig (at 45°F). The high-end pressure is measured at condensing temperature and the low-end pressure is measured at evaporator saturation temperature. Table 1 (continued) DuPont™ Freon®22 Saturation Properties — Temperature Table. 7. Table 2 DuPont™ Freon®22 Superheated Vapor — Constant Pressure Tables. V = Volume in m3/kg H = Enthalpy in kJ/kg S = Entropy in kJ/kg•K Saturation Properties in ( ) 8. Table 2 (continued) DuPont™ Freon®22 Superheated Vapor — Constant Pressure Tables.According to the American Heart Association (AHA), more than 100 million people in the United States are living with high blood pressure (HBD). And that’s a big problem. This condi... You can make ads in the Engineering ToolBox more useful to you! The relation between temperatures and boiling pressuress for. R-717 : Ammonia. R-134a : Tetrafluoroethane. R-22 : Hydrochlorofluorocarbon. R-507 : R-290 : Propane. R-744 : CO 2. are indicated in the diagrams below: This script determines the gas pressure based on temperature of R410a refrigerant. R410A is an HFC refrigerant, invented by Honeywell, that has been developed to replace the HCFC refrigerant R22. Systems operating on R410A run at a pressure of about 1.6 times that of similar systems operating on R22. Energy efficiency is comparable to R22. R22 pressures, Refrigerant R-22 Pressure / Temperature chart Absolute pressure KPA Gauge pressure KG/CM2 KPA-G T T T HVACSuite.com. 36 2.53 248.2 3.56 3,495 349,537 349.5 50.7 13.2 -10.4 262.7 37 2.60 255.1 3.63 3,564 356,431 356.4 51.7 14.2 -9.9 263.3 38 2.67 262.0 3.70 3,633 363,326 363.3 52.7 15.2 -9.3 263.8, R22 has a very similar boiling point to R290 (-41.4°F to 44°F; that’s only a 2.6°F difference). At 100°F, however, the pressure of R22 is 195.9 psig and the pressure of R290 has a pressure of 174.3 psig (check the R290 PT chart below). This is a 20+ psig difference and you will easily tell if you have an R290 or R22 freon., May 29, 2016 ... Converting a R22 system to R407c. NathansHVAC ... Pressures, Temps, Tips! AC Service Tech LLC ... How To Refill R22 AC With Subcooling Method., Search By Vehicle Number Plate. Enter your vehicle number plate below, click 'Search' and we will find the tyre pressure for your vehicle. If you are using your vehicle to carry an additional load or weight, always consult your vehicle handbook for the correct laden pressure. If the tyre size shown does not match the tyre size on your vehicle ..., Jake Clark, certified flight instructor, discusses the oil pressure gauge on the R22., on R22.. i generally use a pressure reading of 150 PSI when the unit is not running on an average 75-80 degree day.. thats on both liquid and suction lines.. for the most part R22 runs pressures of 75-85 PSI suction and 210-225 liquid when the unit is running with proper charge on an average 80 degree day.., Freon™ 407C has been a popular R-22 replacement because of its properties, which include: Similar cooling capacity, energy efficiency, and pressures as R-22 in systems. An ability to be topped off after a leak, multiple times, with minimal impact on system performance. Safety; Freon™ 407C has an ASHRAE A1 safety classification., Jan 22, 2024 · The perfect refrigerant reading depends on several factors, like atmospheric pressure and temperature. I like to see an average range of 58-85 PSI on the low side and 120-300 PSI on the high side. These indicate that the unit is running okay and should be cooling properly. TL;DR: R22 is almost phased out and even banned. , Sep 9, 2016 ... ... pressures well enough that metering changes aren't necessary. This video shows how to convert a R22 system to R407c. At least 20 ..., R22 has a very similar boiling point to R290 (-41.4°F to 44°F; that’s only a 2.6°F difference). At 100°F, however, the pressure of R22 is 195.9 psig and the pressure of R290 has a pressure of 174.3 psig (check the R290 PT chart below). This is a 20+ psig difference and you will easily tell if you have an R290 or R22 freon. , What would you do without a working vehicle? It’s one of your most important possessions. And the fuel pressure regulator is arguably among its most important parts. Discover what ..., Using farthest outside scale on gauge. generally it should be around 225 on the high side and near 70 on the low. Keeping this in consideration, what should my Pressures be for r22? Example R-22 Refrigerant Temperature vs Pressure Data. Ambient Temperature in °F 1. R22 Vapor Pressure at Sea Level. R-22 Low Side Pressure 2. 95°F (35°C) 181.9 ... , R22 gauge pressure is 10.9 bar or 158.2 psi. High side pressure typically varies by equipment and metering controls. Low pressure or suction side typically varies by equipment. Low-pressure refrigerant turns on the carrier HVACR at 50 psi (R22 pressure at 30 degrees) and closes at 100 psi (R22 pressure at 85 degrees)., Search By Vehicle Number Plate. Enter your vehicle number plate below, click 'Search' and we will find the tyre pressure for your vehicle. If you are using your vehicle to carry an additional load or weight, always consult your vehicle handbook for the correct laden pressure. If the tyre size shown does not match the tyre size on your vehicle ..., TIRE LOAD LIMITS (LBS.) AT VARIOUS COLD INFLATION PRESSURES * NEVER exceed the sidewall markings for the maximum loads and inflation pressures. Note: Letters in parentheses denote Load Range for which Bold Face loads are maximum. International Load Index numbers are shown after the Load Range. Tire Size PSI 70 75 80 85 90 95 100 105 110 115 120 ..., For thermodynamic performance to be optimized particular attention must be paid to the fluid&#x2019;s thermal pressure coefficients and thermodynamic properties. A new analytical expression based on the statistical mechanics is derived for R11, R13, R14, R22, R23, R32, R41, and R113 refrigerants, using the intermolecular forces theory. In …, Aug 21, 2018 · August 21, 2018. R-22 was the most popular refrigerant used in commercial and residential air conditioning units for many years because it was considered a safe and cost-efficient refrigerant choice by the HVACR industry. But as anyone in the industry knows, R-22 was phased out in the U.S. beginning in 2010 because it is ozone depleting. , Using the formulas provided: Condensing Temperature = 35°C + 10°C = 45°C. Evaporation Temperature = 27°C – 20°C = 7°C. These calculations serve as rough estimates. To ascertain the operational pressures of the compressor: For R22 refrigerant: High pressure is approximately 1.75 MPa. Low pressure is approximately 0.6 MPa., For light trucks at 65 to 80 psi, add 5 psi. Then for Class A RVs at 100 to 110, you should add 10 psi from the recommended minimum. There are a lot of details that need to be considered as well as the age …, Suction Pressure/EVAP DTD Rule of Thumb Another common old-school rule of thumb is that suction pressure should be close to the outdoor temperature in an R22 system. However, this rule of thumb (obviously) does not work on an R-410A system. A more applicable guideline is 20°-25° suction saturation below outdoor ambient., Actual Line Temp – Sat Temp = Total Superheat. 55°F - 37°F = 18°F. 18°F of Total Superheat > 9°F Target Superheat = Undercharged. Since the actual total superheat measured is higher than the target superheat, we would need to add refrigerant a little at a time until the superheat is the same as the target superheat., According to the Center for Disease Control (CDC) there are approximately 75 million American adults (32%) who have high blood pressure. However, only half of those actually have t..., In this HVAC Refrigerant Charging Video I go over what it means to have low R22 Freon or Low R410A Suction Vapor Pressure along with a Low Superheat. I expla..., Pressure Temperature Charts. °F. °C. R-22. -40. -40.0. 0.5. -35. -37.2., High oil pressure occurs when an unusually high amount of pressure is required to circulate oil through the engine of a car. Most cars have oil pressure gauges that show how much p..., issues due to pressure variations. • Equipment’s reliability is put at risk. • Service personnel are at risk when the type of installed refrigerant is unknown (i.e., use of flammable refrigerants). Topping o˜: R-22 becomes contaminated when systems are …, Argument #1: Pressure. Tube-side materials in R-410A coils need to be thicker due to the higher operating pressures associated with R-410A relative to R-22. We’re not arguing that there’s not a difference in operating pressure between the two. There is – roughly 130 PSI for R-410A evaporators compared to about 70 for R-22., Whether you have an established pressure washing business or you're just getting started, our pressure washing equipment list will help ensure you have everything you need. If you ..., The compound gauge at left is used on the low pressure side of the system and shows pressure readings in black, from 0 to 300 psi gauge pressure. [Click any image to see an enlarged, detailed version.] Temperature corresponding to pressure is shown in red on this gauge for R12 and R22, or for newer refrigerants on newer gauges., Hello what pressures should I see with my system, R22 4 Ton Goodman unit installed in '97. Take into account Texas at 100°F outside ambient temp. I think it may be a bit low on refrigerant judging from the indoor air temps only drop about 15° in to out, it used to do better than that. Thanks! , Low-Pressure Suction Side. The low-pressure side, when connected to the gauge, should read less than 100 psi. PSI is the common measurement for pressure used in terms of pounds per square inch. By the time the refrigerant reaches these lines it has lost most of its heat and has collapsed into a liquid state, taking up less volume., All air conditioners use an oil to keep the compressor lubricated during operation. R-22 air conditioners use mineral oil and R-410A systems use synthetic oil. The synthetic oil is generally more soluble with R-410A than mineral oil is with R-22. This means the R-410A system operates more efficiently reducing wear and tear on the compressor., R22 Refrigerant - Properties - Imperial Units; Temperature (o F) Pressure (psia) Liquid Density (lb/ft 3) Vapor Volume (ft 3 /lb) Enthalpy (Btu/lb) Entropy (Btu/lb o F) Liquid …